Our service

Centre Testing International Co., Ltd. (CTI) is the pioneer and leader in the TIC Industry which provides one-stop solutions on testing, inspection, certification, calibration, audit, training & technical services.

 

By Industry

Our service capabilties cover the upstream and downstream of the supply chain including textile and apparel,toys,electronic appliances,medical health,food...andother industries.

Specialty

Comprehensively guarantee quality and safety, promote compliance and innovation, demonstrate brand competitiveness, and achieve higher quality, healthier, safer, and greener sustainable development.

AUTHORITY & TRUST
QUALITY & VALUE
Industrial Chemicals Environmental Management (Register) Instrument of of Australia testing service

For the Australian Industrial Chemicals Environmental Management (Registration) Act, Chinese manufacturers need to focus on 21 substances listed in Annexes 6 and 7. Centre Testing International Group Co., Ltd. (CTI) can provide testing services for these 21 substances to help products enter the Australian market smoothly.

Industrial Chemicals Environmental Management (Register) Instrument of of Australia testing service

Service Background: 

On March 23, 2022, the Australian government released Australia’s industrial chemicals roadmap to implement the Australian Industrial Chemicals Environmental Management Standards (IChEMS), which outlines the key steps, roles, and responsibilities for transitioning to IChEMS. The Industrial Chemicals Environmental Management (Register) Instrument  includes 7 schedules, with stricter control over industrial chemicals that are likely to cause serious or irreversible harm to humans and the environment. The most environmentally sensitive industrial chemicals are listed in schedules 6 and 7, and all uses of the chemicals listed in schedules 6 and 7 should be phased out.

 

Schedule 6

Substances

The requirments

Effective time

Decabromodiphenyl ether and nonabromodiphenyl ether (congeners)  

CAS:1163-19-5

63936‑56‑1

63387-28-0

437701-79-6

437701-78-5 

for chemical substances10mg/kg

for articles the sum of all tetra‑, penta‑, hexa‑, hepta‑, octa‑, nona‑ and decaBDE congeners 500 mg/kg

for electrical and electronic equipment PBDEs 1000mg/kg

2025.7.1

Dechlorane Plus® and its two constituent isomers, syn-Dechlorane

Plus and anti-Dechlorane Plus (DP, syn-DP and anti-DP)CAS:13560-89-9,135821-03-3,135821-74-8

Prohibited

2026.7.1

Phenol, 2-(2H-benzotriazol-2-yl)-4,6-bis(1,1-dimethylpropyl) (UV-328)CAS:25973-55-1

Prohibited

2026.7.1

  

Benzene, 1,1'-(1,2-ethanediyl)bis[2,3,4,5,6-pentabromo- (Decabromodiphenyl ethane, DBDPE)

CAS number: 84852-53-9. In addition, chemical substances which contain a proportion of DBDPE such as the following CAS number: 1092834-40-6

for substances or mixtures≤10mg/kg

for articles≤500mg/kg

there is a transition period for finished articles that are required to comply with fire retardancy standards, and where no viable alternative

  2027.1.1

Mercury and mercury compounds.

Prohibited

2026.7.1

 

Schedule 7

Substances

The Requirments

Effective Time

Polychlorinated biphenyls(PCBs)

CAS:1336-36-3 etc.

≤2mg/kg, dye and pigment≤50mg/kg

2025.7.1

1,3‑Butadiene, 1,1,2,3,4,4‑hexachloro‑

CAS:87-68-3

Prohibited

2023.7.1

Benzene, 1,2,3,4,5‑pentachloro‑

CAS:608-93-5

Prohibited

2024.7.1

Hexabromobiphenyl

Prohibited

2023.7.1

Hexabromocyclododecane

CAS: 25637-99-4, 3194-55-6, 134237-50-6, 134237-51-7 134237-52-8

100mg/kg

2024.7.1

Hexachlorobenzene

CAS: 118-74-1

10mg/kg

2025.7.1

Octabromodiphenyl ether, heptabromodiphenyl and hexabromodiphenyl ether ( congeners)

CAS32536-52-068928-80-336483-60-0

for chemical substances10mg/kg

for articles the sum of all tetra‑, penta‑, hexa‑, hepta‑, octa‑, nona‑ and decaBDE congeners 500 mg/kg

for electrical and electronic equipment PBDEs 1000mg/kg

2024.7.1

Pentabromodiphenyl ether and tetrabromodiphenyl ether (congeners)  CAS40088-47-932534-81-9

for chemical substances10mg/kg

for articles the sum of all tetra‑, penta‑, hexa‑, hepta‑, octa‑, nona‑ and decaBDE congeners 500 mg/kg

for electrical and electronic equipment PBDEs 1000mg/kg

2024.7.1

Perfluorohexanesulfonic acid (PFHxS), its salts and  PFHxS‑related substances

PFHxS and its salts0.025mg/kg

individual PFHxS‑related compounds or a combination of those compounds1mg/kg

 PFHxS and its salts0.1mg/kg for present in fire‑fighting foam for liquid fuel vapour suppression and liquid fuel fire (Class B fires) already installed in systems, including both mobile and fixed systems)

2025.7.1

Perfluorooctanesulfonic acid (PFOS), its salts and PFOS‑related substances

PFOS and its salts0.025mg/kg

individual PFOS‑related compounds or a combination of those compounds1mg/kg

PFOS and its salts0.8 mg/kg for present in fire‑fighting foam for liquid fuel vapour suppression and liquid fuel fire (Class B fires) already installed in systems, including both mobile and fixed systems

2025.7.1

Perfluorooctanoic acid (PFOA), its salts and PPFOA‑related substances

PFOA and its salts0.025mg/kg

individual PFOA‑related compounds or a combination of those compounds1mg/kg

PFOA and its salts0.8 mg/kg for present in fire‑fighting foam for liquid fuel vapour suppression and liquid fuel fire (Class B fires) already installed in systems, including both mobile and fixed systems

2025.7.1

Polychlorinated naphthalenes

Prohibited

2023.7.1

Polychlorinated terphenyls (PCTs)

CAS:61788-33-8 etc.

2mg/kg

2025.7.1

Short chain chlorinated paraffins

CAS: 85535-84-8, 68920-70-7, 71011-12-6,  85536-22-7, 85681-73-8, 108171-26-2

For substance1%for article0.15%

2024.7.1

 

 

Testing service for the Australian Industrial Chemicals Environmental Management Standards (IChEMS).

Risk assessment of materials.

Internal and supplier management training and consulting services.

 

Our Strengths

CTI has many advanced equipments and has passed CMA/CNAS qualification accreditation, the test data is accurate and reliable, and the test report has international credibility.

▪ The scientific laboratory information management system ensures the efficient operation of each service link.

▪ The technical expert team has rich practical experience and can provide professional, rapid and comprehensive one-stop service.

▪ The service network is all over the world, and many first-line brands designate cooperative laboratories

 

Consult customer service confirm the test plan fill in the application form send the sample pay the test fee test send the report and invoice

 

 

Is the Australian Industrial Chemicals Environmental Management Standards (IChEMS) mandatory?
Yes, it is mandatory. Non-compliant products cannot be exported to Australia.

Which substances should the electronics and electrical industry focus on under the Australian Industrial Chemicals Environmental Management Standards (IChEMS)?
Key substances to monitor are those listed in Schedule  6 and Schedule 7 of the regulation, totaling 23 items.

What are the testing lead time and sample requirements?
The standard testing lead time is 5 working days, and the required sample quantity is 30g.

Related recommendations